Deficiency Index

Tremont Health & Rehabilitation Center

Tremont, Pennsylvania · CCN 395499

22 surveys since 2011. The first finding at harm level was recorded in 2016.

Data as of , released by CMS on October 8, 2026. Source: CMS Provider Data Catalog.

Citations on record
55
Surveys
22
Harm or worse
1
Immediate jeopardy
0
The record, 2011–2026
’11’15’20’25’26
No harm recordedHarm or worseNot surveyed
Harm or worse1

Findings where a surveyor recorded actual harm to a resident.

Beyond CMS’s monthly file16/22

Older surveys no longer in CMS’s monthly file or on Care Compare. They are shown here.

The facility

Certified beds
180
Ownership
For profit - Limited Liability company
Chain
SABER HEALTHCARE GROUP
County
Schuylkill · rural
Medicare-certified since
1981

CMS ratings

Overall
5
Health inspection
4
Staffing
2
Quality measures
5

CMS’s own Five-Star ratings.

Compared with similar facilities

Since 2021, this facility recorded fewer weighted findings than most of its peer group.

Weighted by harm level, against 173 for-profit facilities with 128 or more beds in Pennsylvania.

Last survey on record

Apr 10, 2026

213 days ago.

Counts surveys with at least one finding. A clean survey leaves no record here, so the real gap may be shorter.

Staffing

MeasureThis facilityPeer median
Nurse hours per resident day3.433.39
Registered-nurse hours per resident day0.54—
Annual nurse turnover42.0%49.6%

As reported by the facility to CMS, beside the peer-group median.

Enforcement

No fines, payment denials or special-focus designation on the current CMS record.

Severity of recent findings

Citations by CMS scope and severity. Rows are harm level, columns are how widespread the finding was.
SeverityIsolatedPatternWidespread
Immediate jeopardyJ—K—L—
Actual harmG—H—I—
No harm, potential for more than minimalD1477.8%E316.7%F—
No harm, potential for minimalA—B15.6%C—
CMS’s current file: 18 of the 55 citations on record.

Most frequently cited here

In CMS’s current monthly file.

  • F5504×

    Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.

  • F6562×

    Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured.

  • F6842×

    Provide appropriate treatment and care according to orders, resident’s preferences and goals.

  • F6892×

    Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

  • F5841×

    Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

In the surveyor’s words

From the most serious findings on record at Tremont Health & Rehabilitation Center, in the surveyor’s own words.

  • No harm, potential for more than minimal, patternF584Apr 10, 2026

    Based on observation, it was determined that the facility failed to provide a safe, clean, and comfortable environment on two of three nursing units. (Nursing Units B, C and E )Findings include: Observations on April 7, 2026, from 10:30 a.m. to April 9, 2026, at 1:00 p.m., revealed the following: The privacy curtain in room [ROOM NUMBER] was stained. In rooms 302, 304, 306, and 312 the air conditioning units were dirty and had a thick layer of dust. The linen closet floors were dusty and dirty under the last shelf. On Unit B, two mechanical lifts and one sit to stand lift were observed and had thick hair and debris wrapped around the wheels. On Unit B, a beverage cart had thick hair and debris wrapped around the wheels two days in a row. […]

  • No harm, potential for more than minimal, patternF550Sep 11, 2024

    Based on clinical record review and resident interview, it was determined that the facility failed to provide services to enhance each resident's quality of life by offering showers as scheduled to four of six sampled residents. (Residents 1, 2, 3, 4) Findings include: Clinical record review revealed that Resident 1 was admitted to the facility on [DATE] with diagnoses that included hypertension and chronic obstructive pulmonary disease . The Minimum Data Set (MDS) assessment dated [DATE], indicated that the resident needed staff assistance for bathing. The resident was to receive a shower twice per week on Monday and Thursday. Review of documentation in the clinical record revealed that the resident only received two showers since admission to the facility on [DATE]. […]

  • No harm, potential for more than minimal, patternF921Sep 11, 2024

    Based on observation it was determined that the facility failed to provide a safe, sanitary, and comfortable environment on two of three nursing units (B and C unit) and the main dining room. Findings include: Observation on the B nursing unit on September 11, 2024, from 10:30 a.m. through 2:00 p.m. revealed the following: The wall paper was peeling and hanging off the wall in multiple areas in the common area across from the nurses' station. The floor outside the door to the janitor's closet had a large accummulation of black dirt. In rooms 101, 102, 104, 105, 106, and 107, the floors were sticky and the tiles had a dull black/brown coating of dirt accummulation. In room [ROOM NUMBER] the heating unit contained peeling paint and cobwebs near the controls. […]

  • No harm, potential for more than minimal, patternF697Apr 7, 2022

    Based on facility policy review, clinical record review, and staff interview, it was determined that the facility failed to ensure pain management included the attempt to provide non-pharmacological interventions to alleviate pain prior to the administration of pain mediation prescribed on an as needed basis for five of 28 sampled residents. (Residents 1, 7, 50, 67, 116) Findings include: Review of the facility policy entitled, Pain Management Protocol, last reviewed May 21, 2021, revealed that non-pharmacological interventions were to be attempted prior to the administration of as needed pain medications. Clinical record review revealed that Resident 1 was admitted on [DATE], with diagnoses [MEDICAL RECORD OR PHYSICIAN ORDER] . […]

  • No harm, potential for more than minimal, patternF921Apr 7, 2022

    Based on observation and staff interview, it was determined that the facility failed to provide maintenance services in order to ensure a safe environment on two of three nursing units and the public restrooms across from the activities area. (C and E nursing units, public restrooms) Findings include: During a tour of the facility on April 6, 2022, from 11:45 a.m., to 12:15 p.m., with the Director of Maintenance revealed water temperatures at the handwashing sink in the women's public restroom across from the activities department were 129 degrees Fahrenheit (F), the men's restroom across from the activities department was 125 degrees (F), C wing nursing unit men's shower room sink 114.0 degrees (F), men's shower 111.4 degrees (F), E wing nursing unit men's shower room sink 114.0 degrees… […]

Read 21 findings in full →The most serious and the most recent: 21 of 55 on record.

Every survey on record

FindingsAt actual harm or above

  • Aug 10, 2026Complaint3 findings
  • Apr 10, 2026Standard8 findings
  • Mar 14, 2025Standard and complaint2 findings
  • Sep 11, 2024Complaint3 findings
  • May 30, 2024Complaint1 finding
  • Feb 23, 2024Standard3 findings
  • Oct 28, 2023Complaint1 finding
  • Mar 10, 2023Standard3 findings
Show the 14 earlier surveys
  • Apr 7, 2022Standard3 findings
  • May 21, 2021Standard3 findings
  • Nov 20, 2020Infection control1 finding
  • Sep 16, 2020Complaint1 finding
  • Jan 3, 2020Complaint1 finding
  • Oct 25, 2019Standard1 finding
  • Nov 30, 2018Standard4 findings
  • Oct 20, 2017Standard2 findings
  • Nov 18, 2016Standard2 findings
  • Sep 14, 2016Complaint1 finding · 1 harm
  • Oct 9, 2015Standard3 findings
  • Feb 27, 2015Complaint1 finding
  • Dec 19, 2013—4 findings
  • Oct 7, 2011—4 findings

Surveys that found no deficiencies are not in CMS’s files and do not appear here.

Comparable facilities

The nearest facilities to this one in the same peer group, by weighted findings.

Deficiency Index is independent and is not affiliated with, endorsed by, or approved by CMS, Medicare, or any government agency. About this data · Report a correction