Deficiency Index

Westport Place Health Campus

Louisville, Kentucky · CCN 185466

10 surveys since 2012, and no finding has been recorded at harm level.

Data as of , released by CMS on October 8, 2026. Source: CMS Provider Data Catalog.

Citations on record
26
Surveys
10
Harm or worse
0
Immediate jeopardy
0
The record, 2012–2026
’12’15’20’25’26
No harm recordedHarm or worseNot surveyed
Harm or worseNone

No finding on record has been cited at harm level or above.

Beyond CMS’s monthly file7/10

Older surveys no longer in CMS’s monthly file or on Care Compare. They are shown here.

The facility

Certified beds
64
Ownership
For profit - Corporation
Chain
TRILOGY HEALTH SERVICES
County
Jefferson
Medicare-certified since
2011

CMS ratings

Overall
5
Health inspection
4
Staffing
4
Quality measures
5

CMS’s own Five-Star ratings.

Compared with similar facilities

Not shown for this facility: too few citations in window (n=8, floor 20).

Last survey on record

Feb 14, 2026

268 days ago.

Counts surveys with at least one finding. A clean survey leaves no record here, so the real gap may be shorter.

Staffing

MeasureThis facilityPeer median
Nurse hours per resident day4.373.66
Registered-nurse hours per resident day1.57—
Annual nurse turnover36.9%45.1%

As reported by the facility to CMS, beside the peer-group median.

Enforcement

No fines, payment denials or special-focus designation on the current CMS record.

Severity of recent findings

Citations by CMS scope and severity. Rows are harm level, columns are how widespread the finding was.
SeverityIsolatedPatternWidespread
Immediate jeopardyJ—K—L—
Actual harmG—H—I—
No harm, potential for more than minimalD562.5%E337.5%F—
No harm, potential for minimalA—B—C—
CMS’s current file: 8 of the 26 citations on record.

Most frequently cited here

In CMS’s current monthly file.

  • F5542×

    Allow residents to self-administer drugs if determined clinically appropriate.

  • F7592×

    Ensure medication error rates are not 5 percent or greater.

  • F6951×

    Provide safe and appropriate respiratory care for a resident when needed.

  • F7611×

    Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.

  • F8121×

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

In the surveyor’s words

From the most serious findings on record at Westport Place Health Campus, in the surveyor’s own words.

  • No harm, potential for more than minimal, patternF880May 1, 2025

    Based on observation, interview, record review, and review of facility's policies. The facility failed to follow infection control precautions for three of four sampled residents with peripherally inserted central catheters used for intravenous medication administration for Resident (R) 41, R197 and R6. Observation on 04/29/2025 at 09:23 AM revealed R197 had a peripheral inserted central catheter in right upper arm without a protective cap placed on end of catheter hub (the entry port distal of the catheter that connects to tubing or a syringe to deliver medication intravenously) leaving hub exposed. Observation on 04/29/2025 at 09:43 AM revealed R6 had a peripheral inserted central catheter in left upper arm without a protective cap placed on end of catheter hub, leaving hub exposed. […]

  • No harm, potential for more than minimal, patternF759Mar 3, 2022

    Based on observation, interview, record review, and review of the facility policies, it was determined the facility failed to ensure a medication error rate of less than 5% for two (2) of three (3) sampled residents (Residents #142 and #143) observed during medication administration. Two (2) errors in medication administration observed during thirty-two (32) medication administration opportunities resulted in a medication error rate of 6.25%. The findings include: A review of the facility policy, Medication Administration General Guidelines, revised 11/2018, revealed if staff could not locate a medication with a current, active order in the medication cart/drawer, then staff searched other areas of the medication cart, medication room, and facility (e.g., other units), if possible. […]

  • No harm, potential for more than minimal, patternF812Mar 3, 2022

    Based on observation, interview, record review and review of facility policy, it was determined the facility failed to ensure one (1) of three (3) ice machines were kept clean and sanitary to prevent foodborne illnesses. This failed practice had the potential to affect all residents and staff. The findings include: A review of the facility policy, Kitchen Equipment Preventative Maintenance, revised 02/08/2018, revealed, staff inspected kitchen equipment monthly, unless otherwise directed. […]

  • No harm, potential for more than minimal, isolatedF554Feb 14, 2026

    Number of residents sampled: Number of residents cited: Review of facility policy titled, Medication Administration - General Guidelines, revised 11/2018, indicated, Medications are administered as prescribed in accordance with good nursing principles and practices and only by persons legally authorized to do so. The policy revealed, B. Administration included, 13) Residents are allowed to self-administer medications when specifically authorized by the attending physician and in accordance with procedures for self-administration of medications. […]

  • No harm, potential for more than minimal, isolatedF695Feb 14, 2026

    Based on observation, interview, and record review, the facility failed to ensure staff provided respiratory care consistent with resident care policies related to cleaning and storage of equipment for 3 of 4 residents sampled for respiratory therapy out of a total sample of 17 residents (Residents (R) 30, 48, and 69). Observations revealed used respiratory equipment not cleaned and/or stored appropriately after use. The findings include:1. Review of facility policy, Respiratory Equipment, last reviewed 12/16/2026, revealed the Overview indicated, To provide infection control guidelines to help prevent infections associated with respiratory therapy equipment and to prevent transmission of infections to residents and staff. The policy also indicated, 2. Oxygen Administration included, j. […]

Read 20 findings in full →The most serious and the most recent: 20 of 26 on record.

Every survey on record

FindingsAt actual harm or above

  • Feb 14, 2026Standard3 findings
  • May 1, 2025Standard and complaint1 finding
  • Mar 3, 2022Standard4 findings
  • Jun 12, 2020Infection control1 finding
  • Oct 20, 2016Standard2 findings
  • Sep 17, 2015Standard2 findings
  • Dec 11, 2014Standard1 finding
  • Feb 13, 2014Standard2 findings
Show the 2 earlier surveys
  • Mar 14, 2013—2 findings
  • Jul 19, 2012—8 findings

Surveys that found no deficiencies are not in CMS’s files and do not appear here.

Comparable facilities

The nearest facilities to this one in the same peer group, by weighted findings.

Deficiency Index is independent and is not affiliated with, endorsed by, or approved by CMS, Medicare, or any government agency. About this data · Report a correction