Deficiency Index

Tioga Medical Center LTC

Tioga, North Dakota · CCN 355034

16 surveys since 2011, 3 of them producing a finding at harm level or worse.

Data as of , released by CMS on October 8, 2026. Source: CMS Provider Data Catalog.

Citations on record
73
Surveys
16
Harm or worse
3
Immediate jeopardy
1
The record, 2011–2026
’11’15’20’25’26
No harm recordedHarm or worseNot surveyed
Immediate jeopardy1

Findings at the most serious level CMS records.

Beyond CMS’s monthly file11/16

Older surveys no longer in CMS’s monthly file or on Care Compare. They are shown here.

The facility

Certified beds
30
Ownership
Non profit - Corporation
Chain
Independent
County
Williams · rural
Medicare-certified since
1978

CMS ratings

Overall
3
Health inspection
4
Staffing
4
Quality measures
1

CMS’s own Five-Star ratings.

Compared with similar facilities

Since 2021, this facility recorded somewhat more weighted findings than its peer group.

Weighted by harm level, against 42 not-for-profit facilities with fewer than 66 beds in North Dakota.

Last survey on record

Jun 3, 2026

159 days ago.

Counts surveys with at least one finding. A clean survey leaves no record here, so the real gap may be shorter.

Staffing

MeasureThis facilityPeer median
Nurse hours per resident day5.954.29
Registered-nurse hours per resident day0.96—
Annual nurse turnover65.5%50.0%

As reported by the facility to CMS, beside the peer-group median.

Enforcement

Fines
$11,408 across 1 penalty

Federal civil money penalties and remedies as CMS currently publishes them. Amounts may still be under appeal.

Severity of recent findings

Citations by CMS scope and severity. Rows are harm level, columns are how widespread the finding was.
SeverityIsolatedPatternWidespread
Immediate jeopardyJ—K—L—
Actual harmG15.3%H—I—
No harm, potential for more than minimalD1684.2%E15.3%F—
No harm, potential for minimalA—B—C15.3%
CMS’s current file: 19 of the 73 citations on record.

Most frequently cited here

In CMS’s current monthly file.

  • F6413×

    Ensure each resident receives an accurate assessment.

  • F6892×

    Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

  • F7582×

    Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.

  • F8802×

    Provide and implement an infection prevention and control program.

  • F5781×

    Honor the resident's right to request, refuse, and/or discontinue treatment, to participate in or refuse to participate in experimental research, and to formulate an advance directive.

In the surveyor’s words

From the most serious findings on record at Tioga Medical Center LTC, in the surveyor’s own words.

  • Immediate jeopardy, isolatedF880Aug 11, 2021

    Based on observation, review of facility policy, review of manufacturer's directions, review of professional reference, and staff interview, the facility failed to ensure staff followed standard infection control practices for 3 of 3 residents (Resident #22, #25, and #26) observed during blood glucose tests with a shared blood glucose meter. Failure to clean and disinfect shared glucose meters and glucose testing supply surfaces has the potential for cross-contamination and may result in the transmission of blood-borne pathogens to other residents. During the recertification survey, the team determined a potential Immediate Jeopardy (IJ) situation existed on the evening of 08/09/21. […]

  • Actual harm, isolatedF600Feb 11, 2025

    Based on review of the facility reported incident (FRI), policy review, and staff interview, the facility failed to protect a resident's right to be free from physical abuse for 1 of 2 sampled residents (Resident #1) who sustained a fracture. Failure to ensure an environment free from abuse resulted in a fracture to Resident #1 and placed all residents at risk for abuse, fear, and anxiety. Findings include: Review of the facility policy titled Abuse, Neglect, and Exploitation occurred on 02/11/25. This policy, dated June 2021, stated, . Resident to Resident Altercations . Residents who are abusive to other residents must be monitored . Documentation must be in place to identify steps taken . the corrective action taken, and follow-up monitoring . 6. Prevention of Abuse . b. […]

  • No harm, potential for more than minimal, patternF641Mar 12, 2025

    42397 46964 Based on record review, review of the Long-Term Care Facility Resident Assessment Instrument (RAI) 3.0 User's Manual (Version 1.19.1), and staff interview, the facility failed to ensure accurate coding of the Minimum Data Set (MDS) for 5 of 12 sampled residents (Resident #3, #8, #9, #17 and #20) and one supplemental resident (Resident #6). Failure to accurately complete the MDS does not allow each resident's assessment to reflect their current status/needs and may affect the accurate development of a comprehensive care plan and the care provided to the residents. Findings include: SECTION H: BLADDER AND BOWEL The Long-Term Care Facility RAI User's Manual, revised October 2024, page H-6, stated, . H0200: Urinary Toileting Program . […]

  • No harm, potential for more than minimal, patternF657Aug 11, 2021

    Based on record review, review of facility policy, resident/resident representative, and staff interviews, the facility failed to ensure staff reviewed and revised comprehensive care plans to reflect the residents' current status for 6 of 13 sampled residents (Resident #3, #8, #11, #16, #20, #26) and 1 supplemental resident (Resident #9) reviewed. Failure to review and revise the care plans limited staffs' ability to communicate needs and ensure continuity of care. Findings include: Review of the facility policy and procedure title Multidisciplinary Care Plan occurred on 08/10/21. This policy, dated August 2003, stated, An interdisciplinary team . […]

  • No harm, potential for more than minimal, patternF658Aug 11, 2021

    INSULIN ADMINISTRATION 1. Based on observation, review of professional literature, and staff interview, the facility failed to follow professional standards of practice for 4 of 4 residents (Resident #16, #22, #25, and #26) observed during insulin preparation and administration. Failure to properly disinfect insulin vials/pens and prepare/administer insulin per manufacturer recommendation may result in insulin contamination and the resident receiving an inaccurate dose of insulin. Findings include: The manufacturer's instructions for the NOVOLOG® FlexPen®, found at https://www.novomedlink.com/content/dam/novonordisk/novomedlink/resources/generaldocuments/NovoLog%20FlexPen%20IFU%20PDF_LOCKED.pdf, stated, . NovoLog® . vial . Step 2. Wipe the rubber stopper with an alcohol swab . Step 11. […]

Read 21 findings in full →The most serious and the most recent: 21 of 73 on record.

Every survey on record

FindingsAt actual harm or above

  • Jun 3, 2026Standard3 findings
  • Mar 12, 2025Standard5 findings
  • Feb 11, 2025Complaint1 finding · 1 harm
  • Feb 5, 2024Standard6 findings
  • Jan 12, 2023Standard and complaint4 findings
  • Aug 11, 2021Standard7 findings · 1 harm
  • Oct 13, 2020Infection control1 finding
  • Dec 4, 2019Standard4 findings
Show the 8 earlier surveys
  • Nov 20, 2018Standard6 findings
  • Dec 7, 2017Standard7 findings
  • Oct 27, 2016Standard4 findings
  • Oct 15, 2015Standard6 findings
  • Oct 8, 2014Standard4 findings
  • Sep 19, 2013—2 findings
  • Sep 19, 2012—3 findings
  • Aug 25, 2011—10 findings · 1 harm

Surveys that found no deficiencies are not in CMS’s files and do not appear here.

Comparable facilities

The nearest facilities to this one in the same peer group, by weighted findings.

Deficiency Index is independent and is not affiliated with, endorsed by, or approved by CMS, Medicare, or any government agency. About this data · Report a correction