Based on observation, staff interview, and review of the dishwasher temperature log sheets, manufacturer's instructions and the 2022 FDA Food code, the facility failed to ensure essential equipment was in safe operating condition in 1 of 1 food preparation areas (kitchen). The census was 74. The findings were: 1. Observation on 6/10/24 at 1:40 PM showed the facility used an Ecolab ES-4000 chemical sanitizing low temperature dishwasher. The temperature of the water was to be monitored at breakfast, lunch and dinner. Review of the Ecolab dishwasher manufacturer's instructions showed the minimum temperature of the wash and rinse water was to be 120 degrees Fahrenheit (F), with a recommended temperature of 140 degrees F. …
F908 citations in Wyoming
Equipment in safe condition · Environmental Deficiencies
Keep all essential equipment working safely.
Data as of , released by CMS on October 8, 2026. Source: CMS Provider Data Catalog.
Against expectation — 2024
Wyoming cites F908 more often than its own record predicts
1.01 times the share F908 takes of citations nationally.
Of every deficiency written in Wyoming in 2024, this is the portion that was F908.
Each state is measured against its own expected share, not against other states.
In the surveyor’s words
What Wyoming surveyors wrote
F908 findings written in Wyoming, one from each severity band recorded here, most serious first.
Severity is as the surveyor wrote it. Some findings had already been corrected before the survey.
What else Wyoming surveyors cite →
Deficiency Index is independent and is not affiliated with, endorsed by, or approved by CMS, Medicare, or any government agency. About this data · Report a correction